Migrate VMs. Transform guest systems automatically.
FCS Beam migrates your virtual machines from VMware vSphere to SUSE Virtualization, OpenStack, Proxmox VE, Hyper-V or KVM/libvirt. FCS Beam automatically transforms the guest operating system for its target. The running source VM needs no FCS Beam agent.
Price guarantee: Do you have a valid quote from a competitor for a comparable migration solution? We will offer you Beam at 20% below it. Simply get in touch via our contact form.
Why the move stalls right now
The contract is pressing
Many existing customers report sharply increased licence and support costs. Anyone who wants to move needs a controlled migration path with traceable steps.
Manual work does not scale
Export, convert, swap drivers, repair the bootloader, redo the networking — for every single machine. What works for five VMs collapses at eighty.
The guest OS is the hard part
Copying a disk is easy. Getting Windows Server to boot without its VMware drivers, and Linux to find its new network card, is the actual work.
Four things that make the difference
Not a pile of scripts, but one continuous path from the source to a running machine.
The guest OS is rebuilt with it
FCS Beam adapts the drivers, bootloader and network configuration of Linux and Windows Server guests for the destination. Removal of VMware components depends on the guest profile and whether they can be safely removed.
No agent in the source VM
FCS Beam reads the disks through its vSphere connection. No FCS Beam agent is installed in your running source VMs. For application-consistent snapshots, FCS Beam uses the VMware Tools already installed.
Copy in advance and control cutover
FCS Beam can make the initial copy while the source VM is running. At cutover, the source is stopped for the required final synchronisation.
Verify the copy and startup at the destination
FCS Beam verifies that the disks were fully transferred and that the target VM starts. As part of acceptance, you check that your applications work as expected.
VM disk data flows directly from the source into the target volumes. The appliance uses the focusnet portal for activation and signed execution plans.
Six phases, one migration
01Plan
FCS Beam inventories the source and checks access, target resources, and network and storage mappings. When wave planning is available in the portal, group selected VMs and cut over one wave at a time. Shared writable source disks are excluded. Guest inspection before copying requires VDDK.
02Replicate
The initial copy transfers the full disks. With a valid baseline and usable Changed Block Tracking (CBT), FCS Beam transfers the changed blocks in follow-up copies.
03Provision
The machine, volumes and network attachment are created on the target platform using the validated mappings. FCS Beam reports transfer status and logs the steps for troubleshooting.
04Rebuild
FCS Beam adapts drivers, the bootloader and networking on the copied system disk offline for the destination. A Morph-VM can perform this step for Windows Server.
05Verify
FCS Beam verifies the completeness of every transferred disk and startup of the target VM. Missing evidence stops the workflow.
06Cut over
After final synchronisation and conversion, the target VM is started for operation. Then check your applications.
Where from, where to, and what runs inside
VMware vSphere
FCS Beam connects to the source through vCenter.
- SUSE Virtualization (Harvester/KubeVirt)An eligible pod network adapter can be retained alongside Multus adapters. FCS Beam checks mappings, adapter order and MAC conflicts.
- OpenStack
- Proxmox VE
- Microsoft Hyper-V
- KVM/libvirtUp to 26 disks in total.
RHEL family
RHEL, CentOS, Oracle Linux, Rocky Linux, AlmaLinux
Debian and Ubuntu
Debian, Ubuntu
SUSE
SUSE Linux Enterprise Server, openSUSE
Windows Server
2016, 2019, 2022, 2025
Current versions are released; older ones we review case by case.
What you need to bring
So you know what you are signing up for before you sign up.
Access to vCenter
An account with enough privileges to inventory machines and export their disks.
VDDK is optional
FCS Beam can read VMware disks without the VDDK library from Broadcom. The built-in NFC reader supports eligible disks. Guest inspection before copying requires VDDK.
Room for the appliance
FCS Beam runs as a virtual appliance in your vSphere environment. Use the focusnet portal to activate and operate it.
FCS Beam is not a replacement for a backup solution. IP retention through L2 stretch applies only to migrations into focusnet Cloud Services. This is a migration feature, not a replication or recovery feature.
Try and order Beam
14 days free with up to 5 VMs.
Beam or manual migration? Do the maths.
Compare licence and admin costs using your own assumptions.
Your assumptions
Beam migrates multiple VMs in one transfer; admin time is incurred per transfer, not per VM.
Manual: export, conversion, drivers/network, testing and rework.
Data volume is for information only. It affects transfer duration, not the licence price; this calculator does not estimate duration.
Your cost comparison
- Manual migration cost
- Cost with Beam
- Annual licence included
- Admin cost included
- Total savings
- Savings per VM
- Admin hours saved
- Transfers
- Manual admin hours
- Admin hours with Beam
- Total data (GB)
Cheapest package combination: 1 × 50 VMs
All amounts excluding VAT. Annual licence with no automatic renewal.
Estimate based on your assumptions, with no promise of actual effort. Negative savings mean additional costs.
All inputs and calculations stay in your browser. The calculator sends no data.
Price guarantee: Do you have a valid quote from a competitor for a comparable migration solution? We will offer you Beam at 20% below it. Simply get in touch via our contact form.
Applies to Beam annual licences on presentation of a valid written quote for comparable scope and term; we review and confirm the quote.
Packages can be combined.
More than 5,000 VMs, a special project or interested in becoming a reference? Talk to us.
Annual licence with no automatic renewal. All prices excluding VAT.
Pay by card or SEPA direct debit; from 161 VMs, by SEPA direct debit or invoice with bank transfer. The full licence is activated only after payment is received.
Your trial starts once you choose your packages in the portal and add a payment method; you are charged only if you explicitly book.
Then select "Book Beam" in the portal.
Without a booking the trial ends automatically. No cancellation needed, no charge.
What people ask first
- How can I try and order Beam?
- 14 days free with up to 5 VMs. Registration only creates your account. See the “Try and order Beam” section on this page for how to start your trial.
- Does the licence renew automatically?
- No. Beam is offered as an annual licence without automatic renewal.
- Do I need VDDK?
- VDDK is optional. If you use it, supply it yourself and confirm your licence. The built-in NFC reader reads eligible disks over the network from the appliance or a source shuttle VM. It needs a valid baseline and usable CBT for incremental copies. HotAdd without VDDK can be explicitly selected for eligible disks and source shuttle pools. Without VDDK, guest inspection takes place during conversion.
- Where does my VM data go?
- VM disk data flows directly from the source into the target volumes. The appliance exchanges configuration data with the focusnet portal for activation and signed execution plans.
- How do I plan a migration in waves?
- With compatible planner and appliance versions, select your VMs in the portal and choose “Create wave plan”. The suggested groups account for known disk sizes and visible capacity limits. Review the groups, choose “Save wave plan” and track the plan under “Wave plans”. Waves replicate in parallel or in sequence. Cutovers run in sequence after approval for the whole plan or confirmation for each wave. You can set optional time slots for cutover. You need existing source and target pools. The VM limits are 250 per wave and 500 per plan. Existing transfers are not split.
- Do I have to migrate to focusnet?
- FCS Beam supports SUSE Virtualization (Harvester/KubeVirt), OpenStack, Proxmox VE, Microsoft Hyper-V and KVM/libvirt as targets. IP retention through L2 stretch applies only to migrations into focusnet Cloud Services.
- Does FCS Beam replace my backup?
- FCS Beam is a migration tool. You still need your backup.
- Which guest operating systems are supported?
- The RHEL family including CentOS, Oracle Linux, Rocky, and AlmaLinux, plus Debian and Ubuntu, SUSE Linux Enterprise and openSUSE, as well as Windows Server 2016 through 2025. Older versions we review case by case.
- Is there a price guarantee?
- Price guarantee: Do you have a valid quote from a competitor for a comparable migration solution? We will offer you Beam at 20% below it. Simply get in touch via our contact form. Applies to Beam annual licences on presentation of a valid written quote for comparable scope and term; we review and confirm the quote.
VMware and vSphere are trademarks. SUSE is a trademark of the SUSE group. Proxmox is a trademark of Proxmox Server Solutions GmbH. OpenStack is a trademark of the OpenInfra Foundation. Microsoft and Hyper-V are trademarks of Microsoft Corporation. They are named descriptively only and imply no partnership.